- &space
- Disk–Drive Modules
- Dual-Bus/Dual-Initiator Configuration
- Restarting the Agent
- agent
- Starting the Agent
- error messages
- Restarting the Agent
- restarting
- Reassigning LUN Ownership
- Upgrading the FLARE Code
- Restarting the Agent
- Allocating Memory for RAID-3 LUNs
- Testing the Upgrade
- See also getagent
- getagent
- starting
- Starting the Agent
- stopping
- Reassigning LUN Ownership
- Allocating Memory for RAID-3 LUNs
- Upgrading the FLARE Code
- auto-reassign
- Using the Auto-Assign Capability in the Case of a Failed SP
- basic configuration
- Basic Configuration
- cabling
- Cabling the Basic Configuration
- battery backup unit
- Optional Battery Backup Unit (BBU)
- adding
- Replacing or Adding a Battery Backup Unit
- location
- Challenge RAID Chassis Tour
- Locating the SPs
- Maintaining and Upgrading Other Components
- Challenge RAID Chassis Tour
- Locating the SPs
- Maintaining and Upgrading Other Components
- part number
- Challenge RAID Kit Contents
- replacing
- Replacing or Adding a Battery Backup Unit
- seating
- Reseating Subassemblies
- status lights
- Optional Battery Backup Unit (BBU)
- BBU. See battery backup unit
- Maintaining and Upgrading Disk Modules
- bind
- Binding Disks Into RAID Units
- bind
- legal configurations
- Binding Disks Into RAID Units
- bind
- planning
- Planning the Bind
- cable
- attaching
- Cabling the Basic Configuration
- part number
- Challenge RAID Kit Contents
- cabling
- basic configuration
- Cabling the Basic Configuration
- dual-bus/dual-initiator configuration
- Cabling the Dual-Bus/Dual-Initiator Configuration
- dual-interface/dual-processor
- Cabling the Dual-Interface/Dual-Processor Configuration
- second CHALLENGE RAID
- Cabling an Additional Challenge RAID Storage System (or Chassis Assembly) on a SCSI–2 Bus Channel
- split-bus configuration
- Cabling the Split-Bus Configuration
- cache
- Setting Up Caching
- add-on, part number
- Challenge RAID Kit Contents
- disabling
- setcache
- Setting Cache Parameters
- enabling
- Setting Cache Parameters
- setcache
- flag in bind
- Binding Disks Into RAID Units
- bind
- flag in chglun
- chglun
- hardware requirements
- Challenge RAID Chassis Tour
- Challenge RAID Configurations
- page size
- setcache
- Setting Cache Parameters
- size
- setcache
- Setting Cache Parameters
- storage-control processor memory required
- Storage–Control Processor (SP)
- Can't open device message
- Restarting the Agent
- Cannot connect to agent message
- Restarting the Agent
- CD-ROM, part number
- Challenge RAID Kit Contents
- CHALLENGE S hookup
- Cabling the Basic Configuration
- CHALLENGE server system
- About This Guide
- chassis
- components
- Challenge RAID Chassis Tour
- front view
- deskside
- Challenge RAID Chassis Tour
- rack
- Challenge RAID Chassis Tour
- chassis assembly
- attaching to rack
- Installing an Additional Chassis Assembly in a Challenge RAID Rack
- installing additional
- Installing an Additional Chassis Assembly in a Challenge RAID Rack
- chglun
- chglun
- clearlog
- clearlog
- clearstats
- clearstats
- command-line interface
- The raidcli Command-Line Interface
- command-tagged queuing
- Enabling Command-Tagged Queuing
- components
- Challenge RAID Kit Contents
- Challenge RAID Kit Contents
- Challenge RAID Chassis Tour
- replacement
- Challenge RAID Kit Contents
- Challenge RAID Kit Contents
- configuration
- basic
- Basic Configuration
- cabling
- Cabling the Basic Configuration
- comparison
- Cabling Challenge RAID Configurations
- disks
- Installing the Challenge RAID Software and Configuring Disks
- dual-bus/dual-initiator
- Dual-Bus/Dual-Initiator Configuration
- cabling
- Cabling the Dual-Bus/Dual-Initiator Configuration
- dual-interface/dual-processor
- Reassigning LUN Ownership
- Dual–Interface/Dual–Processor Configuration
- cabling
- Cabling the Dual-Interface/Dual-Processor Configuration
- dual-SP
- Reassigning LUN Ownership
- file
- Creating a Configuration File
- split-bus
- Split–Bus Configuration
- Cabling the Split-Bus Configuration
- cabling
- Cabling the Split-Bus Configuration
- system
- Challenge RAID Configurations
- type 9
- Reconfiguring the Challenge RAID Storage System as System Type 9
- conventions
- Conventions
- CTQ. See command-tagged queuing
- Enabling Command-Tagged Queuing
- dassmgr
- Reconfiguring the Challenge RAID Storage System as System Type 9
- device
- The raidcli Command-Line Interface
- Using raidcli Commands
- name
- Getting the Device Name With raidcli getagent
- node, creating
- Creating Device Nodes and Binding the Disks
- node,creating
- Installing the Challenge RAID Software
- disk module
- Disk–Drive Modules
- A0, B0, C0, A3
- removing
- Labeling Disk Modules
- A0, B0, C0, D0, E0
- failed
- Identifying and Verifying a Failed Disk Module
- failed:and caching
- Setting Up Caching
- Determining Caching Problems
- Identifying and Verifying a Failed Disk Module
- removing
- Installing an Add-On Disk Module Array
- Maintaining and Upgrading Disk Modules
- Labeling Disk Modules
- add-on array
- Installing an Add-On Disk Module Array
- installing
- Installing an Add-On Disk Module Array
- installing:order
- Inserting the New Disk Module Array
- ordering
- Installing an Add-On Disk Module Array
- configuring
- Installing the Challenge RAID Software and Configuring Disks
- identifying failed
- Identifying and Verifying a Failed Disk Module
- installing replacement
- Installing a Replacement Disk Module
- labeling
- Labeling Disk Modules
- location
- Maintaining and Upgrading Disk Modules
- Challenge RAID Chassis Tour
- Labeling Disk Modules
- Inserting the New Disk Module Array
- part numbers
- Challenge RAID Kit Contents
- removing failed
- Removing a Failed Disk Module
- seating
- Labeling Disk Modules
- status lights
- Disk–Drive Modules
- Identifying and Verifying a Failed Disk Module
- unbinding
- Unbinding the Disk
- Unbinding Disks
- dual-bus/dual-initiator configuration
- Dual-Bus/Dual-Initiator Configuration
- cabling
- Cabling the Dual-Bus/Dual-Initiator Configuration
- dual-interface/dual-processor configuration
- Dual–Interface/Dual–Processor Configuration
- Cabling the Dual-Interface/Dual-Processor Configuration
- cabling
- Cabling the Dual-Interface/Dual-Processor Configuration
- dual-SP configuration
- Reassigning LUN Ownership
- electrostatic discharge damage (ESD), avoiding
- Avoiding Electrostatic Discharge (ESD) Damage
- environment variable
- Using raidcli Commands
- The raidcli Command-Line Interface
- Equipment View
- Using RAIDGUI to Enable Auto-Assign
- error codes
- getlog
- event log
- getlog
- failover
- Using RAIDGUI to Enable Auto-Assign
- RAID-3 memory requirement
- Allocating Memory for RAID-3 LUNs
- Determining RAID Levels
- RAID-3 and Failover
- Allocating Memory for RAID-3 LUNs
- See also high availability, IRIS FailSafe configuration
- Determining RAID Levels
- fan module
- Fan Module
- closing
- Opening and Closing the Fan Module
- Opening and Closing the Fan Module
- location
- Challenge RAID Chassis Tour
- Locating the SPs
- Challenge RAID Chassis Tour
- Maintaining and Upgrading Other Components
- Maintaining and Upgrading Other Components
- Locating the SPs
- locking
- Reseating Subassemblies
- Powering On Challenge RAID
- opening
- Opening and Closing the Fan Module
- Opening and Closing the Fan Module
- Powering Off the SP
- part number
- Challenge RAID Kit Contents
- replacing
- Replacing a Fan Module
- system operation when open
- Powering Off the SP
- unlocking
- Reseating Subassemblies
- Powering On Challenge RAID
- filesystem capacity and RAID
- Filesystem Capacity Considerations for RAID
- filler board for storage-control processor, removing
- Removing an SP
- firmware
- getagent
- firmware
- Updating the Disk Module Firmware
- getagent
- for fast RAID-3
- Planning a RAID-3 Bind
- reboot
- Allocating Memory for RAID-3 LUNs
- See also FLARE code
- firmware
- updating after disk replacement
- Updating the Disk Module Firmware
- FLARE code
- See also firmware
- firmware
- upgrading Sauna 7.xx to Sauna 8.xx
- Upgrading FLARE 7.xx to FLARE 8.xx for Sauna
- upgrading Sauna to Phoenix
- Upgrading the FLARE Code
- front bezel, attaching
- Installing an Additional Chassis Assembly in a Challenge RAID Rack
- FRU
- location
- Maintaining and Upgrading Other Components
- Locating the SPs
- Locating the SPs
- Maintaining and Upgrading Other Components
- deskside
- Challenge RAID Chassis Tour
- rack
- Challenge RAID Chassis Tour
- part numbers
- Challenge RAID Kit Contents
- fx
- Enabling Command-Tagged Queuing
- getagent
- getagent
- Getting the Device Name With raidcli getagent
- getcache
- getcache
- getcontrol
- getcontrol
- getcrus
- getcrus
- getdisk
- getdisk
- getlog
- getlog
- getlun
- getlun
- getsp
- Allocating Memory for RAID-3 LUNs
- high availability
- Dual-Bus/Dual-Initiator Configuration
- Binding Disks Into RAID Units
- bind
- See also failover
- Determining RAID Levels
- hot spare, binding
- bind
- idle
- delay time
- chglun
- threshold
- chglun
- inst
- Installing the Challenge RAID Software
- IRIS FailSafe configuration
- Dual-Bus/Dual-Initiator Configuration
- Replacing or Adding an SP
- Cabling the Dual-Bus/Dual-Initiator Configuration
- Using the Auto-Assign Capability in the Case of a Failed SP
- IRIX version required
- About This Guide
- kit contents
- Challenge RAID Kit Contents
- LUN
- Binding Disks Into RAID Units
- ownership
- Using the Auto-Assign Capability in the Case of a Failed SP
- restoring ownership
- Reassigning LUN Ownership
- See also disk module, bind, unbind
- Binding Disks Into RAID Units
- MAKE_VLUNS
- Creating Device Nodes and Binding the Disks
- MAKEDEV
- Installing the Challenge RAID Software
- memory module
- configurations
- Installing or Removing SP Memory Modules (SIMMs)
- installing
- Installing SP Memory Modules
- part number
- Challenge RAID Kit Contents
- removing
- Removing SP Memory Modules
- midplane, part number
- Challenge RAID Kit Contents
- model number
- SP
- getsp
- Oracle Parallel Server configuration
- Dual-Bus/Dual-Initiator Configuration
- Cabling the Dual-Bus/Dual-Initiator Configuration
- owner's guide, part number
- Challenge RAID Kit Contents
- Page Stream = chapter
- upgrading to LIC 9.X in storage system
- Upgrading to FLARE 9.xx in a Storage System With RAID-3 LUNs
- part numbers
- Challenge RAID Kit Contents
- power cord, part number
- Challenge RAID Kit Contents
- power distribution unit
- part number
- Challenge RAID Kit Contents
- replacing
- Replacing the Power Distribution Unit in a Challenge RAID Rack
- power receptacle, part number
- Challenge RAID Kit Contents
- power supply
- Power Supply Module (Voltage Semi-Regulated Converter)
- adding
- Replacing or Adding a Power Supply Module
- location
- Locating the SPs
- Challenge RAID Chassis Tour
- Maintaining and Upgrading Other Components
- Maintaining and Upgrading Other Components
- Challenge RAID Chassis Tour
- Locating the SPs
- part number
- Challenge RAID Kit Contents
- replacing
- Replacing or Adding a Power Supply Module
- seating
- Reseating Subassemblies
- status lights
- Power Supply Module (Voltage Semi-Regulated Converter)
- power switch location
- Locating the SPs
- Maintaining and Upgrading Other Components
- powering
- off
- Reseating Subassemblies
- on
- Powering On Challenge RAID
- rack
- adding chassis assembly
- Installing an Additional Chassis Assembly in a Challenge RAID Rack
- opening rear door
- Opening the Rear Door of a Challenge RAID Rack
- replacing power distribution unit
- Replacing the Power Distribution Unit in a Challenge RAID Rack
- setting up
- Setting Up a Challenge RAID Rack
- RAID
- and filesystem capacity
- Filesystem Capacity Considerations for RAID
- level 1_0
- disk module order
- Binding Disks Into RAID Units
- bind
- level 3
- allocating memory
- Allocating Memory for RAID-3 LUNs
- planning
- Planning a RAID-3 Bind
- setting memory
- Setting Cache Parameters
- setcache
- striping
- Binding Disks Into RAID Units
- levels
- planning
- Determining RAID Levels
- RAID levels, binding
- bind
- raid5-agent.config
- Creating a Configuration File
- Restarting the Agent
- RaidAgentDevice environment variable
- The raidcli Command-Line Interface
- Using raidcli Commands
- raidcli
- The raidcli Command-Line Interface
- parameters summarized
- The raidcli Command-Line Interface
- parsing without calling API
- Using raidcli Commands
- syntax
- Using raidcli Commands
- The raidcli Command-Line Interface
- verbose
- Using raidcli Commands
- RAIDGUI, starting
- Using RAIDGUI to Enable Auto-Assign
- rebuild time
- bind
- Installing a Replacement Disk Module
- bind
- Binding Disks Into RAID Units
- chglun
- chglun
- restarting
- agent after changing RAID-3 memory
- Allocating Memory for RAID-3 LUNs
- rip controller, part number
- Challenge RAID Kit Contents
- Sauna
- upgrading 7.xx to 8.xx
- Upgrading FLARE 7.xx to FLARE 8.xx for Sauna
- upgrading to Phoenix
- Upgrading Sauna to Phoenix
- SCSI-2
- adapter
- SCSI–2 Interface
- bus length limit
- Cabling an Additional Challenge RAID Storage System (or Chassis Assembly) on a SCSI–2 Bus Channel
- Cabling an Additional Challenge RAID Storage System (or Chassis Assembly) on a SCSI–2 Bus Channel
- cable
- attaching
- Cabling the Basic Configuration
- attaching. See also cabling
- Cabling an Additional Challenge RAID Storage System (or Chassis Assembly) on a SCSI–2 Bus Channel
- internal I/O, part number
- Challenge RAID Kit Contents
- part number
- Challenge RAID Kit Contents
- connectors on CHALLENGE RAID chassis
- Cabling the Basic Configuration
- ID
- SPs:first CHALLENGE RAID
- Setting SCSI IDs for Storage-Control Processors
- SPs:second CHALLENGE RAID
- Setting SCSI IDs for SPs in a Second Challenge RAID on the Same SCSI–2 Bus Channel
- switches:first CHALLENGE RAID
- Setting SCSI IDs for Storage-Control Processors
- switches:second CHALLENGE RAID
- Setting SCSI IDs for SPs in a Second Challenge RAID on the Same SCSI–2 Bus Channel
- interface
- SCSI–2 Interface
- internal I/O cable, part number
- Challenge RAID Kit Contents
- terminator plug, attaching
- Cabling the Basic Configuration
- setcache
- setcache
- setstats
- setstats
- SIMM
- configurations
- Installing or Removing SP Memory Modules (SIMMs)
- installing
- Installing SP Memory Modules
- part number
- Challenge RAID Kit Contents
- removing
- Removing SP Memory Modules
- software, installing
- Installing the Challenge RAID Software
- SP. See storage-control processor
- Maintaining and Upgrading Disk Modules
- split-bus configuration
- Split–Bus Configuration
- cabling
- Cabling the Split-Bus Configuration
- status light
- battery backup unit
- Optional Battery Backup Unit (BBU)
- disk module
- Disk–Drive Modules
- fan module
- Fan Module
- power supply
- Power Supply Module (Voltage Semi-Regulated Converter)
- storage-control processor
- ready
- Storage–Control Processor (SP)
- service
- Storage–Control Processor (SP)
- storage-control processor
- Storage–Control Processor (SP)
- failed, and caching
- Determining Caching Problems
- Setting Up Caching
- filler board, removing
- Removing an SP
- installing
- Installing an SP
- location
- Challenge RAID Chassis Tour
- Challenge RAID Chassis Tour
- Maintaining and Upgrading Other Components
- Maintaining and Upgrading Other Components
- Locating the SPs
- Locating the SPs
- memory for caching
- Storage–Control Processor (SP)
- memory module
- installing
- Installing SP Memory Modules
- removing
- Removing SP Memory Modules
- minimum system memory
- Storage–Control Processor (SP)
- part number
- Challenge RAID Kit Contents
- Challenge RAID Kit Contents
- Challenge RAID Kit Contents
- powering off
- Powering Off the SP
- powering on
- Powering On Challenge RAID
- Installing an SP
- removing
- Removing an SP
- replacing
- Replacing or Adding an SP
- seating
- Reseating Subassemblies
- setting SCSI ID
- first CHALLENGE RAID
- Setting SCSI IDs for Storage-Control Processors
- second CHALLENGE RAID
- Setting SCSI IDs for SPs in a Second Challenge RAID on the Same SCSI–2 Bus Channel
- status lights
- Storage–Control Processor (SP)
- stripe size
- Binding Disks Into RAID Units
- bind
- striping
- count
- bind
- Binding Disks Into RAID Units
- RAID-3
- Binding Disks Into RAID Units
- system type 9, reconfiguring as
- Reconfiguring the Challenge RAID Storage System as System Type 9
- technical specifications
- Technical Specifications
- terminator plug, part number
- Challenge RAID Kit Contents
- trespass
- trespass
- Reassigning LUN Ownership
- troubleshooting
- Troubleshooting
- unbind
- Unbinding Disks
- Unbinding the Disk
- unbind
- user documentation, part number
- Challenge RAID Kit Contents
- VSC. See power supply
- Maintaining and Upgrading Disk Modules