Chapter 1. Challenge RAID Kit Contents


Note: Before installing a Challenge RAID storage system, make sure that the installation site meets the AC power requirements and operating limits listed in Appendix A.

This chapter summarizes the contents of the Challenge RAID kit.


Note: If parts are missing, or if incorrect parts are included in the kit, please log a call with the Technical Assistance Center (TAC).

Table 1-1 lists components included with the unit.

Table 1-1. Challenge RAID Components

Component

SGI Part Number

5-foot SCSI external differential cable w/2-56 jack screws

9290112

20-foot SCSI external differential cable w/2-56 jack screws

9290111

Power cord for destination country

See Table 1-4

CD and document package:

CD Challenge RAID software 2.1

CD SCSI patches 8505XL

CHALLENGE RAID Owner's Guide

013-1200-005

813-0322-004

813-0412-001

007-2532-007

Table 1-2 lists disk module part numbers. Disk modules can be replaced by customers as well as by SSEs.

Table 1-2. Disk Module Part Numbers

Disk Module

Marketing Code

Part Number

Replacement 2 GB drive

P-S-RAID-1X2

9410117

Replacement 4 GB drive

P-S-RAID-1X4

9410118

Add-on five 2 GB drives

P-S-RAID-5X2

9410115

Add-on five 4 GB drives

P-S-RAID-5X4

9410116

Table 1-3 gives the marketing codes for the basic Challenge RAID storage system configurations.

Table 1-3. Challenge RAID Storage System Marketing Codes

Disk Array

Marketing Code

Part Number

Base array with five 2 GB drives

P-S-RAID-B5X2

9410100

Base array with five 4 GB drives

P-S-RAID-B5X4

9410101

Rack with no chassis assemblies

P-S-RAID-RACK

9470109

Export rack with no chassis assemblies

P-S-RAID-ERACK

9470110

Chassis assembly with five 2 GB drives

P-S-RAID-R5X2

9470107

Chassis assembly with five 4 GB drives

P-S-RAID-R5X4

9470108

Table 1-4 lists marketing codes for power cord destination kits for the deskside chassis.

Table 1-4. Deskside Power Cable Destination Kits

Marketing Code

Cable

DK-P4-001

115V (US and Japan)

DK-P4-002

220V (Europe: Austria, Belgium, Netherlands, Luxembourg, Finland, France, Germany, Norway, Sweden, Spain, Portugal, Greece, Iceland, Yugoslavia, Bolivia, Peru, Paraguay, Venezuela, Iran, Indonesia)

DK-P4-003

220V (UK, Singapore, Hong Kong, Malaysia)

DK-P4-004

220V (Denmark)

DK-P4-005

220V (Switzerland)

DK-P4-006

220V (Italy, Chile)

DK-P4-007

220V (India, South Africa)

DK-P4-008

220V (Israel)

DK-P4-009

220V (Australia)

DK-P4-010

115V (Japan, Korea, Taiwan)



Note: All destination kits include the SCSI Differential terminator plug with 2-56 jack screws (p/n 9660006).

Table 1-5 lists marketing codes for power cord destination kits for the rack.

Table 1-5. Rack Power Cable Destination Kits

Marketing Code

Cable

DK-T4-001

115V (US)

DK-T4-004

220V (international)

Table 1-6 lists field-replaceable units (FRUs), that is, units only a Silicon Graphics SSE is qualified to replace.

Table 1-6. Field-Replaceable Units

Component

Marketing Code

Part Number

Storage-control processor (SP), no cache

P-S-RAID-SP0

9470119

Storage-control processor (SP)

P-S-RAID-SP

9470111

Storage-control processor (SP) with additional 8 MB mirroring

P-S-RAID-SP8

9470112

Storage-control processor (SP) with 32 MB mirroring

P-S-RAID-SP32

9470120

Storage-control processor (SP) with 64 MB mirroring

P-S-RAID-SP64

9470113

Power supply module (VSC)

P-S-RAID-PWR

9470114

Power receptacle (rack only)

N/A

005-38429

Power distribution unit for rack (domestic only)

N/A

005-042667

Rip controller

N/A

005-041325

Midplane

N/A

005-041324

SCSI internal I/O cable

N/A

005-040575

Storage-control processor (SP)

P-S-RAID-SP

9400103

Battery backup unit (BBU) (optional)

P-S-RAID-BBU

9341100

Fan module with 6 fans

P-S-RAID-FAN

9310103

Add-on 8 MB mirrored cache

P-S-RAID-C8

9390100

4 MB SIMM (included in 8 MB mirrored cache)

N/A

variable

Add-on 64 MB mirrored cache

P-S-RAID-C64

9390101

16 MB SIMM (included in 64 MB mirrored cache)

N/A

variable