This appendix contains the following sections:
Table A-1 provides the dimensions for the SGI 2 Gb TP9100 enclosure, tower, and rack.
Dimension | Rackmount Enclosure | Tower Enclosure | Rack |
|---|---|---|---|
13.4 cm (5.3 in.) | 50.1 cm (19.7 in.) | Operating: 180 cm (5.94 ft) Shipping: 210 cm (6.93 ft) | |
Width | 44.6 cm (17.5 in.) | 23 cm (9 in.) | Operating: 60 cm (1.98 ft) Shipping:120 cm (3.96 ft) |
Depth | 50 cm (19.7 in.) | 52.3 cm (20.6 in.) | Operating: 81 cm (2.64 ft) Shipping: 120cm (6.93 ft) |
Table A-2 shows the weight s of various component modules.
Component | Weight |
|---|---|
Enclosure, fully populated | Rackmount: 32.3 kg (71 lb) Tower: 42.3 kg (93.0 lb) |
Enclosure, empty | Rackmount: 17.9 kg (39.4 lb) Tower: 12 kg (26.4 lb) |
Power supply/cooling module | 3.6 kg (7.9 lb) |
Disk carrier module with 36-GB drive | 0.88 kg (1.9 lb) |
LRC I/O module | 1.2 kg (2.6 lb) |
Tower conversion kit | 10 kg (22 lb) |
Table A-3 shows the power requirements and specifications of the 2 Gb TP9100.
Table A-3. Power Specifications
Specification | Value |
|---|---|
Voltage range for Rack | 200-240 VAC |
Voltage range for Tower | 100-120/220-240 VAC |
Voltage range selection | Automatic |
Frequency | 50-60 Hz |
Power factor | >0.98 |
Harmonics | Meets EN61000-3-2 |
Power cord: Plug Socket |
SV or SVT, 18 WG minimum, 3 conductor 250 V, 10 A IEC 320 C-14, 250 V, 15 A |
Table A-4 provides temperature and humidity requirements for both the rack and tower storage systems.
Table A-4. Ambient Temperature and Humidity Requirements
Factor | Temperature | Relative Humidity | Maximum Wet Bulb |
|---|---|---|---|
Operating temperature | 5 °C to 40 °C | 20% to 80% noncondensing | 23 °C |
Non-operating temperature | 0 °C to 50 °C | 8% to 80% noncondensing | 27 °C |
Storage temperature | 1 °C to 60 °C | 8% to 80% noncondensing | 29 °C |
Shipping temperature | -40 °C to +60 °C | 5% to 100% nonprecipitating | 29 °C |
Table A-5 gives other environmental specifications for both the rack and tower storage systems.
Table A-5. Environmental Specifications
Environmental Factor | Requirement |
|---|---|
Altitude, operating | 0 to 3047 m (0 to 10,000 ft) |
Altitude, non-operating | -305 to 12,192 m (-1000 to 40,000 ft) |
Shock, operating | Vertical axis 5 g peak 1/2 sine, 10 ms |
Shock, non-operating | 30 g 10 ms 1/2 sine |
Vibration, operating | 0.21 grms 5-500 Hz random |
Vibration, Non-operating | 1.04 grms 2-200 Hz random |
Acoustics | Less than 6.0 B LwA operating at 20 °C |
Safety and approvals | CE, UL, cUL |
EMC | EN55022 (CISPR22-A), EN55024 (CISPR24), FCC-A |
Table A-6 provides minimum storage system power requirements.
Table A-6. Minimum Power Requirements
Factor | Requirement |
|---|---|
Tower: 100 to 120 or 220 to 240 VAC | |
Frequency | 50 to 60 Hz |
Maximum power consumption | 700 VA |
Typical power consumption | 400 VA or less |
Inrush current (25 °C (77 °F) cold start 1 PSU) | 100 A maximum peak for 4ms, 25 A thereafter at maximum voltage |
Table A-7 provides additional information for the power distribution units (PDUs) in the rack.
Table A-7. Rack PDU Power Specifications
Factor | Requirement or Specification |
|---|---|
Ratings | 200 to 240 VAC, 24 A, 50 to 60 Hz |
Over-voltage category | |
Maximum load per PDU | 24 A |
Maximum load per bank of outlet sockets on each circuit breaker | 10 A |
Plug | NEMA L6-30 |
Table A-8 provides specifications for the LRC I/O module.
Table A-8. LRC I/O Module Specifications
Specification | Value |
|---|---|
Connectors | 2 x SFP module LC optical, maximum cable length 300 m 1x SFP expansion port, maximum copper cable length 1 m |
External FC-AL signal cables | SGI dual-port HBAs: 25 m (82 ft) for information on cables) |
Drive interface | 2 x FC-AL loops, connected internally to FCAL LRC I/O |
Power dissipation | 3 A @ 3.3 V 2 A @ 5 V 2 A @ 12 V |
RAID levels | 0, 1, 3, 5, and 0+1 (RAID level 6) |
LED Indicators | Drive loop signal good - green Host port 1 and 2 signal good - green Cache active - green RAID active - green RAID fault - amber ESI/LRC module fault LED - amber |
Memory | 512 MB maximum |
Cache | Selectable write-through or write-back |
Battery | NiCad cache battery protects 512 MB data for up to 72 hours |
Consult your supplier for details of disk drives supported for use with the RAID storage system. Table A-9 provides specifications for a typical drive carrier module.
Table A-9. Drive Carrier Module Specifications (1.6-inch 36-GB Drive)
Factor | Requirement |
|---|---|
Dimensions | Height 2.91 cm (1.1 in.) Width 10.65 cm (4.2 in.) Depth 20.7 cm (8.1 in.) |
Weight | .88 kg (1.9 lb) with 36-GB drive |
Operating temperature | 5 °C to 40 °C (41 °F to 104 °F) when installed |
Power dissipation | 22 W maximum |
Table A-10 lists SGI cable options that can be connected to the 2 Gb TP9100 product.
Table A-10. SGI Fibre Channel Fabric Cabling Options for the 2 Gb TP9100 Storage System
Length | Marketing Code | Part Number | |
|---|---|---|---|
1 m copper SFP to copper SFP cable | 1 m (3.3 ft) | TP912G-CASCADE | 018-1081-001 |
FC optical cable (62.5 μm) | 3 m (9.8 ft) | X-F-OPT-3M | 018-0656-001 |
| 10 m (32.8 ft) | X-F-OPT-10M | 018-0656-101 |
| 25 m (82 ft) | X-F-OPT-25M | 018-0656-201 |
| 100 m (328 ft) | X-F-OPT-100M | 018-0656-301 |
| 300 m (980 ft) [a] | X-F-OPT-300M | 018-0656-401 |
[a] This cable is not authorized for use with SGI Fibre Channel switches. | |||