This appendix summarizes technical data for the Fibre Channel Hub:
Table A-1 summarizes Fibre Channel Hub physical specifications.
Table A-1. Fibre Channel Hub Physical Specifications
Specification | Value |
---|---|
Chassis dimensions | Height: 43 cm (1.7 in.) |
Weight | |
ANSI standard | |
Bit rate | |
Voltage | |
Power | |
Operating temperature | |
Operating humidity |
The hub ports use the ANSI FC-PH standard DB-9 pinout with an additional power pin to support an external module for electrical-to-optical conversion. Figure A-1 shows Fibre Channel Hub DB-9 pinout.
Table A-2 lists Fibre Channel Hub copper connector specifications.
Table A-2. Copper Connector Specifications
Pin | Signal | Direction |
---|---|---|
1 | TX+ | Output |
2 | MIA power supply | VCC |
3 | Fault- | NC |
4 | Key | NC |
5 | RX+ | Input |
6 | TX- | Output |
7 | ODIS+ | Output |
8 | MIA ground | GND |
9 | RX- | Input |
At the right on the front panel of the Fibre Channel Hub is an RJ11 port for communicating with the system console. Table A-3 shows specifications for this connector.
Table A-3. Console (Serial) RJ11 Connector Specifications
Pin | Signal | Description |
---|---|---|
1 | DTR | Data Terminal Ready |
2 | TXD | Transmit Data |
3 | GND | Ground |
4 | RXC | Receive Data Common |
5 | RXD | Receive Data |
6 | DSR | Data Set Ready |
The front panel also has a standard 10-Base-T Ethernet port, above the serial port.
The factory defaults are the recommended settings. Table A-4 summarizes factory defaults.
Table A-4. Fibre Channel Hub Factory Defaults