This appendix lists the technical specifications for the Challenge RAID deskside disk-array storage systems. Table A-1 summarizes specifications for the deskside storage system.
Table A-1. Challenge RAID Deskside Chassis Specifications
Classification | Specification | Value |
---|---|---|
AC power requirements | Voltage Current draw Power consumption | 90 VAC to 264 VAC, single-phase autoranging 47 Hz to 63 Hz 9.0 A max at 100 VAC input Apparent power: 900 VAC max |
Connector | Type | L6-15R/L6-15P |
Operating limits | Ambient temperature Relative humidity Elevation Host dissipation Shock Vibration | 10 degrees C to 38 degrees C 20 to 80% noncondensing 2439 m (8000 ft) 3168 x 103 J/hr (3000 Btu/hr) max 3 g @ 11 ms 0.25 g peak @ 5 Hz to 500 Hz |
Nonoperating limits (shipping and storing) | Ambient temperature Gradient, maximum Relative humidity Elevation | -40 degrees C to 65 degrees C 24 C/hr (43.2 degrees F/hr) 10 to 90% noncondensing 7625 m (25,010 ft) |
Physical | Dimensions Minimum chassis weight Maximum chassis weight Disk drive module Third power supply module Second storage-control processor Battery backup unit | Height: 62.9 cm (24.75 in.) Chassis with 5 disk modules, 1 SP, 2 VSCs, without packaging: 51.6 kg (114.0 lb) Chassis with 20 disk modules, 2 SPs, 3 VSCs, BBU, without packaging: 83.9 kg (184.5 lb) 1.6 kg (3.5 lb) 2.4 kg (5.3 lb) 1.2 kg (2.6 lb) 5.4 kg (12 lb) |
Service clearance | Front Rear | 81.3 cm (32.0 in.) 81.3 cm (32.0 in.) |
Buses | External host bus Internal storage system buses | Differential fast and wide SCSI–2 (synchronous) Five single–ended SCSI buses |
Table A-2 summarizes specifications for the rack storage system.
Table A-2. Challenge RAID Rack Specifications
Classification | Specification | Value |
---|---|---|
AC power requirements | Cabinet voltage Current draw per chassis assembly Power consumption per chassis | 200 VAC to 240 VAC, single-phase 47 Hz to 63 Hz 5.0 A max at 200 VAC input Apparent power: 1000 VAC max |
Connector | Type | Domestic: L6-30P/L6-30R |
Operating limits | Ambient temperature Relative humidity Elevation Heat dissipation per chassis Shock Vibration | 10 degrees C to 38 degrees C 20 to 80% noncondensing 2439 m (8000 ft) 3168 x 103 J/hr (3000 Btu/hr) max per chassis assembly 3 g @ 11 ms 0.25 g peak @ 5 Hz to 500 Hz |
Nonoperating limits (shipping and storing) | Ambient temperature Gradient, maximum Relative humidity Elevation | -40 degrees C to 65 degrees C 24 C/hr (43.2 degrees F/hr) 10 to 90% noncondensing 7625 m (25,010 ft) |
Physical | Cabinet dimensions Maximum cabinet weight Table A-1 for weights of FRUs. | Height: 180.34 cm (71.0 in.) 407.96 kg (899.4 lb): 4 chassis assemblies, each with 20 disk modules, 2 SPs, 3 power supplies, battery backup unit, without packaging
|
Service clearance | Front access Rear and side access | 81.3 cm (32.0 in.) 76.2 cm (30.0 in.) |
Buses | External host bus Internal storage system buses | Differential fast and wide SCSI–2 (synchronous) Five single–ended SCSI buses |